Analyser system for waste incinerator, steel and cement industry, for use in high temperature applications. The system measures gases, such as CO, O2, CH4, NO, SO2, CO2 etc. In order to save energy and maintain stable process conditions, on-line gas analyser systems is a must in mordern cement production. Continuous measurement has been practiced for serveral years, but not very successfully. The instability of earlier technologies has prevented the use of automatic control. Though reliable measurement of NO, O2 and CO it is possible to optimize both calgination and klinker burning. The HITEM 2000 System The HITEM 2000 system consists of three elements:
The advantages of the system is amoung others:
|
||||||
|
|
Sampling system for kiln inlet or calciner applications. HT 2000 P is the automated sample gas probe in the liquid cooled sampling system. The probe is designed for gas sampling in high temperature and high dust applications, such as kiln inlet and calciner outlet in the cement industry. It is equally suitable for furnace applications in steel plants, lime industry and similar with high temperature and heavy dust content. The probe is furnished with connections for cooling liquid supplied from the cooling unit. A heated filter is flanged to the probe. It has built-in ball valve for heavy blow back. The purge air is preheated for higher efficiency. The atomatic retraction device is equipped with a pneumatic drive for inserting into and retracting the gas sampling probe from the measuring point. This is not only for convenience but also for safety. In case of an emergency situation, such as lack of cooling liquid due to power loss, the probe is brought out in a safe position. Also too high temperature or missing coolant flow is detected and will result in immediate withdrawal from the hot proces. A compressed air container ensures sufficient air for safe retraction at plant air failure. The device is controlled by the HT 2000 A, Analyser and Control Unit. It can also be manually operated either via the touch screen or a local control panel at the probe. Technical data probe: Sample filter
Probe
|
||||||||||||||||||||||||
|
|
Technical data:
Heat exchanger
Pump
Flowmeter
Temperature transmitter
|
|||||||||||||||||||||||||
|
|
The Analyser and Control Unit is the heart of the liquid cooled sample system. The cabinet contains all necessary sample conditioning such as gascooler, condensate separator, solenoid valves, pumps, filters and flow- and humidity monitors. The components are arranged in an optional way in respect of response time, durability and service. A PLC controls all functions of the analyser unit. It also collects information from the cooling unit and controls the automatic retraction device and filter blow back. It is equipped with a touch screen for intelligent HMI. All settings and control functions are done via touch screen, such as:
The touch screen also gives information about alarms, possible faults that can have given the alarm and what to do. Flow sheets of the different units in the system are displayed. By touching a component on the flow sheet an explanation of the components function in the system appears on the screen. |
||||||
![]() |